PPA5531 (Three-phase, IEC6100-3-2/3/11/12 and IEC61000-4-11/13 Compliant, DC & 10mHz to 1MHz, 100mApk to 1000Apk (50Arms) Harmonic and Flicker Analyzer)


Brand: N4L
Model Series: PPA55x1 Series
Category:

About Product

The N4L PPA55x1 Series Power Analyzers are precision Harmonics and Flicker Analyzers which provide fully compliant test and measurement solutions to meet the latest IEC61000-3-2, IEC61000-3-3, IEC61000-3-11 and IEC61000-3-12 Harmonics and Flicker international test standards. The PPA55x1 Series offer both standalone and software driven test ability, giving the user the option to obtain pass/fail results on the instrument with no requirement for a PC. The IECSoft can be used to offer the user an intuitive and highly sophisticated reporting and analysis platform. The PPA55x1 Series Harmonics and Flicker Analyzers are supplied with UKAS ISO17025 certification for Voltage, Current and Power as standard and this is performed at N4L in the UK in own accredited ISO17025 Laboratory.

N4L URL : http://www.newtons4th.com/products/power-analyzers/ppa55x1-harmonics-and-flicker/

Product Features

 Fully compliant to IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-3-12, IEC61000-4-11and IEC61000-4-13 standard requirements
 UKAS ISO17025 accredited
 Frequency range: DC and 10mHz to 1MHz
 Leading wideband accuracy: Basic 0.01% with class leading high frequency performance
 Basic phase accuracy 0.005° necessary for low power factor applications
 Fast sample rate and no-gap: 2.2M samples/s
 High precision internal shunts superior accuracy to any external shunt
 50Arms (1000Apk) & 1000Vrms (3000Vpk) direct input
 Sophisticated data reporting: Enables user to determine failure modes accurately
 PC software: Remote control, tables, graphs and database management of results
 N4L IMP Series Impedance Networks are available for IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-3-12, IEC61000-4-11 and IEC61000-4-13 compliance measurements. N4L IMP161 (Single-phase, 10Arms), IMP163 (Three-phase, 20Arms), IMP323 (Three-phase, 32Arms) and IMP753 (Three-phase, 75Arms) Impedance Networks are available for customer’s selection
 N4L N4A Series AC Power Sources are available for IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-3-12, IEC61000-4-11 and IEC61000-4-13 compliance measurements. N4L N4A03 (Single-phase, 3kVA, 10Arms), N4A06 (Single-phase, 6kVA, 20Arms), N4A18 (Three-phase, 18kVA, 20Arms/Phase), N4A30 (Three-phase, 30kVA, 32Arms/Phase) and N4A67 (Three-phase, 67.5kVA, 75Arms/Phase) are available for customer’s selection
 1 to 3 phase: Ability to perform single-phase (PPA5511) and three-phase (PPA5531) measurements
 Various measurement modes Power, Harmonic, RMS, LCR, Scope, Integrator
 PWM motor drive measurements: Highest performance Analyzer on the market for PWM motor drive evaluation
 DFT real time no gap analysis
–  Many power applications have fast changing asynchronous current pulses which are not suited to fixed data length FFT analysis. The PPA55x1 Series combine a real time DFT (Discrete Fourier Transform) technique with variable window no gap analysis to ensure the optimum speed and accuracy at all times (See photo section)
 Use in conjunction with the optional N4L ADI40 40 Channel Analogue< >Digital Interface to build a powerful multi-channel measurement system
 IECSoft Software is provided as standard
–  The IECSoft Software provides a sophisticated harmonics real time graph display giving analogue representation of data in order for the user to have the ability to quickly and easily determine failure modes of any DUT
 Versatile interfaces: LAN, GPIB, USB, RS232 are provided as standard

Product Functions

 Fully compliant to IEC61000-3-2/IEC61000-3-3 in 10Arms Single-phase Harmonics and Flicker Measurements when IMP161 Impedance Network is used with N4L PPA5511 Harmonics and Flicker Analyzer and N4L N4A03/N4A06/N4A18/N4A30/N4A67 AC Power Source. UKAS ISO17025 Calibration is optional
 Fully compliant to IEC61000-3-2/IEC61000-3-3 in 16Arms Single-phase Harmonics and Flicker Measurements when IMP161 Impedance Network is used with N4L PPA5511 Harmonics and Flicker Analyzer and N4L N4A06/N4A18/N4A30/N4A67AC Power Source. UKAS ISO17025 Calibration is optional
 Fully compliant to IEC61000-3-2/IEC61000-3-3 in 16Arms Three-phase Harmonics and Flicker Measurements when IMP163 Impedance Network is used with N4L PPA5531 Harmonics and Flicker Analyzer and N4L N4A18/N4A30/N4A67AC Power Source. UKAS ISO17025 Calibration is optional
 Fully compliant to IEC61000-3-11/IEC61000-3-12 in 32Arms Three-phase Harmonics and Flicker Measurements when IMP323 Impedance Network is used with N4L PPA5531 Harmonics and Flicker Analyzer and N4L N4A30/N4A67 AC Power Source. UKAS ISO17025 Calibration is optional
 Fully compliant to IEC61000-3-11/IEC61000-3-12 in 75Arms Three-phase Harmonics and Flicker Measurements when IMP753 Impedance Network is used with N4L PPA5531 Harmonics and Flicker Analyzer and N4L N4A67 AC Power Source. UKAS ISO17025 Calibration is optional
 IEC61000-3-2/12: Fluctuating Harmonics measurement (See photo section)
 IEC61000-3-3/11: Flicker measurement (See photo section)
 1MHz wideband frequency response
–  With 1MHz bandwidth and exceptionally flat response, PPA55x1 Series provide precision analysis of total power in applications such as lighting ballasts or PWM drives that involve a wide range of frequency components. Proprietary to N4L, a digital process called Expanded Nyquist Sampling ensures no alias components
 Inductance loss analysis (See photo section)
 Power analysis
–  All power measurement and RMS values are computed simultaneously allowing measured values to be selected and viewed during analysis (See photo section)
 Power Integrator (power consumption) mode, RMS Meter mode and Impedance Meter mode (See photo section)
 Harmonic Analyzer (See photo section)
 Oscilloscope (See photo section)
 Switched inrush current testing (See photo section)
 Fully automated report generation (See photo section)

Product Application

 Fully compliant Harmonics and Flicker test solutions
 Standby power (IEC62301 Ed 2.0)
–  The N4L PPA55x1 Series offer unrivalled dynamic range which enables the user to comply with IEC62301 and Energy Star testing standards. Utilizing “Standby Power Mode”, the PPA employs proprietary standby power signal processing algorithms to provide accurate no gap analysis of high crest factor (CF) signals, importantly the entire N4L power analyzer range benefit from a guaranteed accuracy specification up to a crest factor of 20 (See photo section)
 PWM motor drive evaluation
–  The PPA55x1 Series Power Analyzers are the perfect solutions for inverter drive evaluation and analysis. Utilizing proprietary digital filtering algorithms, the N4L power analyzer range offers unrivalled performance. The PPA55x1 Series can be used in conjunction with external current sensors such as the WR5000 – a 1MHz 5000A Rogowski Coil in high current applications as well as the LEM range of Current Output CT. Inverter efficiency is available via either 3 Phase 2 Wattmeter method + CH3 (utilizing CH3 for the DC Bus measurement). Alternatively a second single-phase PPA can be connected to the DC Bus and the two analyzers are configured in a Master Slave arrangement, all data is available via N4L software (See photo section)
 Power transformer loss testing
–  The PPA55x1 Series exhibit the best phase accuracy on the market, with a basic accuracy of 0.005° low power factor core loss testing of transformers is both accurate and repeatable. N4L PPA55x1 Series are supplied with UKAS ISO17025 Certificate of Calibration (See photo section)
 Inrush current measurement
–  Accurate inrush current measurements rely upon two factors aside from fundamental measurement accuracy. These are gapless measurement and a high sampling rate. For gapless measurement, inrush waveforms by their nature are transient; gapless measurement is vitally important in order to ensure that inrush waveform data is not missed. For the high sampling rate, when working with mains frequencies, many power analyzers have low sample rates due to the computation of measured values from a data block of finite size. The PPA55x1 Series utilize a proprietary real time signal processing technique that maintains full 2.2Ms/s sample rate irrespective of the measured load frequency, ensuring that high frequency events are captured without aliasing (See photo section)

Standard Accessories

A. LAN Interface
B. GPIB Interface
C. USB Interface
D. RS232 Interface
E. Leads: Power, RS232, USB, GPIB
F. Connection Cables: 1.5m, 36A 4mm Stackable Terminals for 1x Red, 1x Yellow and 2x Black per Phase
G. Connection Clips: 4mm Terminated Alligator Clips – 1x Red, 1xYellow and 2x Black per Phase
H. CDROM: IECSoft, CommView2 (RS232/USB/LAN), Command line, Script-based Communication Software
I. Documents: User Manual, Communications Manual, Calibration Certificate, Quick Start Guide

Product Options

A. PPA5511-F2: Additional Voltage Card for measurement of Flicker at the output of the AC Source (PPA5511)
B. PPA Data Logger: PPA Series Control and Data Acquisition PC Software
C. PPAcomm: Basic PC Control, Data Storage, Print Features
D. PPAsoft: PC Software with Control, Data Save and Print Functions
E. PPA Standby Power: Standby Power Measurements and Reporting to IEC62301
F. Impedance Network: IMP161, IMP163, IMP323, IMP753
G. N4A AC+DC Power Source: N4A03, N4A06, N4A18, N4A30, N4A67
H. ADI40: 40 Channel Analogue< >Digital Interface
I. ADI40 Rack Mounting Brackets: 19″ Rack Mounting Brackets for ADI40
J. Breakout Box: Simple Analyzer Connection between Source and DUT
K. Voltage Break Out Lead Set: 3 x 2m BNC to BNC with 4mm Banana Voltage Break Out Leads + 2 x Voltage Low Shorting Leads
L. USB to 9-Pin RS232: USB to 9-Pin RS232 Serial Converter
M. PCIS: Phase Controlled Inrush Switch – 10Arms-300Apk Inrush Switch with External Port Ribbon Cable
N. GPIB Communication Cable: GPIB Communication Cable Option
O. 36A 4mm to Spade: 1.5m, 36A Lead Set with 4mm to Spade for HC Terminals
P. DC Isolator: Torque and Speed Input Isolator
Q. Master-Slave Connection Leads: Extension Port Cable with Adaptor plus BNC to BNC Sync Lead
R. RM Brackets: Brackets and Fixing Screws for 19″ Rack Mounting
S. Soft Carry Case: Black Nylon Padded Case with Accessory Space, Handle and Shoulder Strap
T. Hard Carry Case: Hard Carry Case
U. ULCP Ultra Low Capacitance Probe (Active): 1.5pF, 1kVrms, DC – 2MHz, 1000:1 Ultra Low Capacitance Probe (Active)
V. TT-HV 250 High Voltage Probe (Passive): 2.5kVpk – 100:1
W. TT-HVP 15HF High Voltage Probe (Passive): 15kVpk – 1000:1
X. ATT10 10:1 Voltage Attenuator: For Connection to PPA Ext Input When Using HV Probes
Y. ATT20 20:1 Voltage Attenuator: For Connection to PPA Ext Input When Using HV Probes
Z. ATT100 100:1 Voltage attenuator: For Connection to PPA Ext Input When Using HV Probes
AA. ATT1000 1000:1 Voltage attenuator: For Connection to PPA Ext Input When Using HV Probes
BB. HF003: 3Arms – 30Apk, DC – 1MHz, Basic Accuracy 470mΩ (±0.1%), Phase Accuracy 0.0001˚ / kHz External Current Shunt, BNC Output (Use with PPA External Input)
CC. HF006: 6Arms – 60Apk, DC – 1MHz, Basic Accuracy 100mΩ (±0.1%), Phase Accuracy 0.001˚ / kHz External Current Shunt, BNC Output (Use with PPA External Input)
DD. HF020: 20Arms – 200Apk, DC – 1MHz, Basic Accuracy 10mΩ (±0.1%), Phase Accuracy 0.01˚ / kHz External Current Shunt, BNC Output (Use with PPA External Input)
EE. HF100: 100Arms – 1000Apk, DC – 1MHz, Basic Accuracy 1mΩ (±0.1%), Phase Accuracy 0.05˚ / kHz External Current Shunt, BNC Output (Use with PPA External Input)
FF. HF200: 200Arms – 2000Apk, DC – 1MHz, Basic Accuracy 0.5mΩ (±0.1%), Phase Accuracy 0.1˚ / kHz External Current Shunt, BNC Output (Use with PPA External Input)
GG. HF500: 500Arms – 5000Apk, DC – 1MHz, Basic Accuracy 0.2mΩ (±0.1%), Phase Accuracy 0.1˚ / kHz External Current Shunt, BNC Output (Use with PPA External Input)
HH. M3 UB 50A-1V: 100mA – 50A, 40Hz – 5kHz, Accuracy 1%, Clamp Diameter 15mm x 17mm, 600V CAT III Category AC Current Clamp
II. M3 U 100A-1V: 1A – 100A, 40Hz – 5kHz, Accuracy 1%, Clamp Diameter 15mm x 17mm, 600V CAT III Category AC Current Clamp
JJ. S UE 200A-1V: 1A – 200A, 40Hz – 5kHz, Accuracy 1%, Clamp Diameter 50mm, 600V CAT III Category AC Current Clamp
KK. S UE 250 500 1000-1V: 1A – 250A/500A/1000A, 40Hz – 5kHz, Accuracy 1% (250A) 0.5% (500+1000A), Clamp Diameter 50mm, 600V CAT III Category AC Current Clamp
LL. US UE 1000A-1V: 1A – 1000A, 40Hz – 5kHz, Accuracy 1%, Clamp Diameter 43mm, 600V CAT III Category AC Current Clamp
MM. SM UE 1000A-1V: 0.5A – 1000A (1% ≥100A), 15Hz – 15kHz, Accuracy 1%, Clamp Diameter 54mm, 600V CAT III Category AC Current Clamp
NN. SM UB 1000A-1V: 0.5A – 1000A (0.5% ≥10A), 15Hz – 15kHz, Accuracy 0.5%, Clamp Diameter 54mm, 600V CAT III Category AC Current Clamp
OO. P32 UE 1000A-1V: 5A – 1000A, 40Hz – 5kHz, Accuracy 1%, Clamp Diameter 83mm, 600V CAT III Category AC Current Clamp
PP. P32 UE 3000A-1V: 5A – 3000A, 40Hz – 5kHz, Accuracy 1%, Clamp Diameter 83mm, 600V CAT III Category AC Current Clamp
QQ. SC 2C 100A-1V: 1A – 100A, DC – 5kHz, Accuracy 2%, Clamp Diameter 50mm, 600V CAT III Category AC + DC Current Clamp
RR. SC 3C 1000A-1V: 1A – 1000A, DC – 2kHz, Accuracy 1%, Clamp Diameter 59mm, 600V CAT III Category AC + DC Current Clamp
SS. P20 3C 2000A-2V: 40A – 1000/2000A, DC – 2kHz, Accuracy 1%, Clamp Diameter 83mm, 600V CAT III Category AC + DC Current Clamp
TT. P40 3C 4000A-2V: 40A – 2000/4000A, DC – 2kHz, Accuracy 1.5%, Clamp Diameter 83mm, 600V CAT III Category AC + DC Current Clamp
UU. P50 3C 5000A-2V: 50A – 2000/5000A, DC – 2kHz, Accuracy 1.5%, Clamp Diameter 83mm, 600V CAT III Category AC + DC Current Clamp
VV. Rogowski WR5000 (1 Phase): Wideband Rogowski 1Apk to 5000Apk, 1Hz to 1MHz Current Transformer
WW. Danisense DS200 Current Output CT (1 Phase): DC – 200Arms, DC – 250kHz
XX. Danisense DS600 Current Output CT (1 Phase): DC – 600Arms, DC – 250kHz
YY. Danisense DS2000 Current Output CT (1 Ph): DC – 2000Arms, DC – 250kHz
ZZ. LEM IT 60-S Current Output CT (1 Phase): 42Arms (60Apk), DC – 800kHz
AAA. LEM IT 65-S Current Output CT (1 Phase): 60Arms (85Apk), DC – 800kHz
BBB. LEM IT 200-S Current Output CT (1 Phase): 141Arms (200Apk), DC – 500kHz
CCC. LEM IT 205-S Current Output CT (1 Phase): 200Arms (283Apk), DC – 1000kHz
DDD. LEM IT 400-S Current Output CT (1 Phase): 282Arms (400Apk), DC – 500kHz
EEE. LEM IT 405-S Current Output CT (1 Phase): 400Arms (566Apk), DC – 300kHz
FFF. LEM IT 605-S Current Output CT (1 Phase): 600Arms (849Apk), DC – 300kHz
GGG. LEM IT 700-S Current Output CT (1 Phase): 495Arms (700Apk), DC – 100kHz
HHH. LEM ITN 600-S Current Output CT (1 Phase): 424Arms (600Apk), DC – 300kHz
III. LEM ITN 900-S Current Output CT (1 Phase): 636Arms (900Apk), DC – 300kHz
JJJ. LEM ITN 1000-S Current Output CT (1 Phase): 707Arms (1000Apk), DC – 300kHz
KKK. LEM LF510-S Current Output CT (1 Phase): 500Arms, Accuracy 0.6% (0.1% with System Calibration), DC – 100kHz
LLL. LEM LF1010-S Current Output CT (1 Phase): 1000Arms, Accuracy 0.4% (0.1% with System Calibration), DC – 100kHz
MMM. LEM LF510/1010 Compatible PSU: Compatible Power Supply Unit for the LF510-S & LF1010-S CT

Related Catalog

PPA5511-PPA5531 Catalog (2017.10.09)

Our Company

Miko, established in 1980, is a leading instrumentation distributor in Hong Kong and China.

Over the years, we have been fully engaged in the sales and marketing of electronic T&M instruments in the territory. Our market sector coverage includes telecommunication, power, data communication, audio, broadcasting and education.